speedvac.thermofisher.comSpeedVac Vacuum Concentrators | Thermo Fisher Scientific - US

speedvac.thermofisher.com Profile

speedvac.thermofisher.com

Maindomain:thermofisher.com

Title:SpeedVac Vacuum Concentrators | Thermo Fisher Scientific - US

Description:Thermo Scientific Savant SpeedVac vacuum concentrators, refrigerated vapor traps and pumps use state-of-the-art centrifugation, vacuum and heat technologies for removing solvents and concentrating samples while maintaining sample integrity.

Keywords:speedvac vacuum concentrator, vacuum concentrator, speedvac, savant...

Discover speedvac.thermofisher.com website stats, rating, details and status online.Use our online tools to find owner and admin contact info. Find out where is server located.Read and write reviews or vote to improve it ranking. Check alliedvsaxis duplicates with related css, domain relations, most used words, social networks references. Go to regular site

speedvac.thermofisher.com Information

Website / Domain: speedvac.thermofisher.com
HomePage size:250.899 KB
Page Load Time:0.04422 Seconds
Website IP Address: 208.89.142.141
Isp Server: Fisher Scientific

speedvac.thermofisher.com Ip Information

Ip Country: United States
City Name: Pittsburgh
Latitude: 40.575496673584
Longitude: -79.722351074219

speedvac.thermofisher.com Keywords accounting

Keyword Count
speedvac vacuum concentrator13
vacuum concentrator21
speedvac31
savant9

speedvac.thermofisher.com Httpheader

Accept-Language: en
Accept-Ranges: bytes
Content-Encoding: gzip
Content-Type: text/html; charset=UTF-8
P3P: CP="CAO PSA OUR"
Server: Apache
X-Akamai-Transformed: 9 39185 0 pmb=mRUM,2
Expires: Sat, 15 May 2021 01:54:47 GMT
Cache-Control: max-age=0, no-cache, no-store
Pragma: no-cache
Date: Sat, 15 May 2021 01:54:47 GMT
Content-Length: 41571
Connection: keep-alive
Vary: Accept-Encoding
Server-Timing: cdn-cache; desc=MISS, edge; dur=-346, origin; dur=373
X-Akam-SW-Version: 0.5.0
X-Host-Header: www.thermofisher.com
X-TLS-Version: tls1.3

speedvac.thermofisher.com Meta Info

content="IE=edge" http-equiv="X-UA-Compatible"/
charset="utf-8"/
content="Thermo Scientific Savant SpeedVac vacuum concentrators, refrigerated vapor traps and pumps use state-of-the-art centrifugation, vacuum and heat technologies for removing solvents and concentrating samples while maintaining sample integrity." name="description"/
content="speedvac vacuum concentrator, vacuum concentrator, speedvac, savant" name="keywords"/
content="index,follow" name="robots"/
content="SpeedVac Vacuum Concentrators - US" name="DC.title"/
content="code-EPy51aiPZe" name="baidu-site-verification"/
content="SpeedVac Vacuum Concentrators | Thermo Fisher Scientific - US" property="og:title"/
content="website" property="og:type"/
content="//www.thermofisher.com/us/en/home/life-science/lab-equipment/speedvac-vacuum-concentrators.html" property="og:url"/
content="Thermo Scientific Savant SpeedVac vacuum concentrators, refrigerated vapor traps and pumps use state-of-the-art centrifugation, vacuum and heat technologies for removing solvents and concentrating samples while maintaining sample integrity." property="og:description"/
content="en_US" property="og:locale"/
content="//www.thermofisher.com" property="og:image"/
content="width=device-width, initial-scale=1.0, maximum-scale=1.0, user-scalable=0" name="viewport"/

208.89.142.141 Domains

Domain WebSite Title

speedvac.thermofisher.com Similar Website

Domain WebSite Title
speedvac.thermofisher.comSpeedVac Vacuum Concentrators | Thermo Fisher Scientific - US
jobs.thermofisher.comCareers at Thermo Fisher Scientific | Thermo Fisher Scientific jobs
thermofisher.comThermo Fisher Scientific - US
info1.thermoscientific.comThermo Fisher Scientific - US
home.appliedbiosystems.comThermo Fisher Scientific - US
www6.appliedbiosystems.comThermo Fisher Scientific - JP
ebioscience.comeBioscience | Thermo Fisher Scientific - US
us.ebioscience.comeBioscience | Thermo Fisher Scientific - US
dionex.comChromatography | Thermo Fisher Scientific - US
mediaex.comThermo Fisher Scientific ordering portal
news.thermofisher.comThermo Fisher Scientific Corporate Newsroom
ir.thermofisher.comThermo Fisher Scientific - Investor Overview
appliedbiosystems.comApplied Biosystems | Thermo Fisher Scientific - US
affymetrix.comMicroarray Analysis | Thermo Fisher Scientific - US
gentek.mediaex.comThermo Fisher Scientific ordering portal

speedvac.thermofisher.com Traffic Sources Chart

speedvac.thermofisher.com Alexa Rank History Chart

speedvac.thermofisher.com aleax

speedvac.thermofisher.com Html To Plain Text

Popular Applications & Techniques Shop All Products Services Support Sign in Quick Order Search Thermo Fisher Scientific Search All Search Home › Life Sciences › Lab Equipment › SpeedVac Vacuum Concentrators SpeedVac Vacuum Concentrators See Navigation ‹ Lab Equipment Cold Storage › Lab Ovens & Furnaces › Lab Hotplates & Stirrers › CO2 Incubators › Microbiological Incubators & Environmental Chambers › Water Baths, Circulators & Chillers › Lab Shakers › Biological Safety Cabinets & Clean Benches › Lab Centrifuges › Lab Water Purification › Orion and AquaSensors Water Analysis Portfolio › Rheometers & Viscometers › Lab Automation › Liquid Handling › Lab Instruments By Application › Microplate Instruments › pH & Electrochemistry › Wireless Monitoring Systems › Hot Plates & Stirrers › SpeedVac Vacuum Concentrators Individual Vacuum Concentrators SpeedVac Vacuum Concentrator Kits Refrigerated Vapor Traps Universal Vacuum Systems SpeedVac Vacuum Concentrator Rotors Lab Vacuum Pumps Chemical Traps SpeedVac Vacuum Concentrator Accessories Savant SpeedVac Kit Selection Guide Dry Baths › › › Online Water Measurement Systems › Individual Vacuum Concentrators Vacuum Concentrator Kits Refrigerated Vapor Traps Universal Vacuum Systems SpeedVac Rotors Pursue new discoveries with speed and precision Samples are precious and so is time. Thermo Scientific Savant SpeedVac vacuum concentrators, refrigerated vapor traps and pumps use state-of-the-art centrifugation, vacuum and heat technologies for removing solvents and concentrating samples while maintaining sample integrity. Choose from any of the nine different models of vacuum concentrator to suit your needs from biological to non-biological samples from low to high volume samples. SpeedVac Selection Guide Watch the video Download SpeedVac eBook Request more information › Featured SpeedVac Vacuum Concentrator Categories Individual Vacuum Concentrators Individual vacuum concentrators for upgrading an existing piece of equipment or when you are looking to build your system from scratch. SpeedVac Vacuum Concentrator Kits From traditional drying down of DNA preparations in water and methanol, to the more complex and aggressive applications presented by the combinatorial chemistry and drug discovery sectors of the pharmaceutical industry, we have the systems for your lab. Refrigerated Vapor Traps Refrigerated Vapor Traps are available with two temperature ranges from ambient temperature to -50°C and ambient temperature to -105°C Universal Vacuum Systems Savant Universal Vacuum Systems are the most energy efficient and environmentally safe vacuum system available, providing complete recovery of evaporated solvents SpeedVac Vacuum Concentrator Rotors Rotors are available in a wide variety of styles and sizes to accommodate all your sample requirements Lab Vacuum Pumps Two pump styles are available from Thermo Scientific: traditional rotary vane oil pumps and the newer oil-free, maintenance free vacuum pumps SpeedVac Vacuum Concentrator Accessories Improve the functionality of Thermo Scientific Savant SpeedVac Concentrators with Savant SpeedVac concentrator accessories Chemical Traps Chemical traps are highly recommended to absorb residual volatile vapors that may bypass the primary cold trap Why use centrifugation for evaporation? Centrifugation generates a centrifugal force to prevent bumping (bubbling), boiling, and physical loss of the sample. To completely dry the sample, the solute is deposited at the bottom of the container for complete quantitative recovery. SpeedVac solvent evaporation examples SPD140DDA , VLP120 , RVT400 4ml Blue H 2 O, 65°C, no lights after 1 hour SPD140DDA , VLP120 , RVT400 4ml, Blue H 2 O, 65°C, no lights Vac 14 torr after 1 hour SPD2030 4ml, Blue H 2 O, 65°C, no lights Vac 0.1 torr after 1 hour SPD140DDA , VLP120 , RVT400 4ml, Blue H 2 O, 65°C, no lights Vac 0.1 torr after 2 hours Vacuum promotes solvent evaporation in the SpeedVac chamber. Samples are maintained in liquid state at sub-ambient temperature throughout the concentration process, preventing loss of activity or damage to heat sensitive substances. By applying a controlled vacuum the boiling point of the solvents can be lowered to the point that the liquid vaporizes with minimal heat which prevents oxidation of samples during the drying process. High performance vacuum pumps ensure the low pressures which are required for faster solvent removal. Heat is applied to the samples to accelerate the evaporation process. SpeedVac Vacuum Concentrators use built-in chamber heaters. Some models are equipped with radiant lamp on the lid to provide additional heat and prevent condensation of the solvents. Smart Note: Savant SpeedVac System When the quality of your results hinges on the quality of synthesized oligos As oligos are being aggressively leveraged in research and clinical applications such as detecting, characterizing, and developing therapeutics and vaccines, the quality of synthesized oligos is critical. The Savant SpeedVac system enhances speed and reliability so you can have complete confidence in the quality of your oligos as well as the applications they serve. Download Featured information Support sample preparation with ease and efficiency Compact and integrated vacuum concentrator for sample safety and reproducible results. Download Sample Evaporation with Thermo Scientific Savant SpeedVac Vacuum Concentrators Some of our website’s features will not work on the browser you’re using. Please update your browser version or choose another browser to use. Watch the video to learn about effective means of sample preparation. x Watch video Questions to consider when selecting a SpeedVac system We have a lot of options available to anyone wanting to concentrate samples using the SpeedVac system. If you are confused as to which one is right for you, review the six questions below to learn more about which SpeedVac is right for your needs. Which SpeedVac is right for me? Question #1: What is the material or solute that you are concentrating or drying? Is it biological or non-biological? We generally break solutes into two categories–biological (DNA, RNA, enzymes, proteins, vaccines, etc.) and non-biological (products of organic synthesis, drug metabolites, pesticides). The sample concentration and drying technique of choice for non-biological materials is vacuum evaporation. These samples are generally in high concentrations of organic solvents and/or strong acids and bases. Vacuum concentration offers rapid concentration of non-biological materials. The main question with biologicals is whether to freeze dry (lyophilize) or vacuum concentrate. Freeze drying is generally recommended when the material is to be stored for long periods of time, must be easily and quickly reconstituted, and needs to retain biological activity (i.e., proteins/enzymes). Most molecular biology applications involving DNA/RNA, in aqueous or aqueous + low concentration organics, use vacuum concentration for sample prep. Consider systems such as the Thermo Scientific™ Savant™ SpeedVac™ DNA130 or SPD1030 . Freeze drying can be performed efficiently in a vacuum concentrator. However, freeze drying requires a deep vacuum (i.e., rotary vane oil pump) to keep the sample frozen during sublimation. Depending on the solute/ solvent and conditions, a properly configured SpeedVac system can be used for either freeze drying or vacuum concentration such as the SpeedVac SPD120P2 . Question #2: What is the solvent that your material is prepared in? If it is an organic solvent, is it an aggressive solvent (methylene chloride, toluene), or a non-aggressive solvent (ethanol, methanol, acetonitrile) or a high-boiling-point solvent (DMSO, DMF)? This is one of the most important decision making factors in the proper choice of a SpeedVac system. Our goal is to give you the most cost-effective solution to your sample prep needs. Due to the need to ...

speedvac.thermofisher.com Whois

"domain_name": [ "THERMOFISHER.COM", "thermofisher.com" ], "registrar": "MarkMonitor, Inc.", "whois_server": "whois.markmonitor.com", "referral_url": null, "updated_date": [ "2019-04-06 09:03:43", "2019-04-06 02:03:43-07:00" ], "creation_date": [ "2006-05-08 06:38:10", "2006-05-07 23:38:10-07:00" ], "expiration_date": [ "2021-05-08 06:38:10", "2021-05-07 00:00:00-07:00" ], "name_servers": [ "PDNS1.ULTRADNS.NET", "PDNS2.ULTRADNS.NET", "PDNS3.ULTRADNS.ORG", "PDNS4.ULTRADNS.ORG", "PDNS5.ULTRADNS.INFO", "PDNS6.ULTRADNS.CO.UK", "pdns1.ultradns.net", "pdns5.ultradns.info", "pdns3.ultradns.org", "pdns6.ultradns.co.uk", "pdns2.ultradns.net", "pdns4.ultradns.org" ], "status": [ "clientDeleteProhibited https://icann.org/epp#clientDeleteProhibited", "clientTransferProhibited https://icann.org/epp#clientTransferProhibited", "clientUpdateProhibited https://icann.org/epp#clientUpdateProhibited", "clientUpdateProhibited (https://www.icann.org/epp#clientUpdateProhibited)", "clientTransferProhibited (https://www.icann.org/epp#clientTransferProhibited)", "clientDeleteProhibited (https://www.icann.org/epp#clientDeleteProhibited)" ], "emails": [ "abusecomplaints@markmonitor.com", "dnsinfo@thermofisher.com", "whoisrequest@markmonitor.com" ], "dnssec": "unsigned", "name": "Domain Administrator", "org": "Thermo Fisher Scientific", "address": "81 Wyman Street,", "city": "Waltham", "state": "MA", "zipcode": "02454", "country": "US"